{"id":4070,"date":"2026-02-16T12:57:55","date_gmt":"2026-02-16T11:57:55","guid":{"rendered":"https:\/\/nlab.idve.pl\/produkt\/insplorion-acoulyte-designed-for-q-sense-window-chamber-fits-q-sense-explorer-e1-analyzer-e4-optics-unit-optical-fiber-probe-90-degree-bifurcated-fiber-insplorion-software\/"},"modified":"2026-06-29T22:39:40","modified_gmt":"2026-06-29T20:39:40","slug":"insplorion-acoulyte-designed-for-q-sense-window-chamber-fits-q-sense-explorer-e1-analyzer-e4-optics-unit-optical-fiber-probe-90-degree-bifurcated-fiber-insplorion-software","status":"publish","type":"product","link":"https:\/\/nlab.pl\/en\/product\/insplorion-acoulyte-designed-for-q-sense-window-chamber-fits-q-sense-explorer-e1-analyzer-e4-optics-unit-optical-fiber-probe-90-degree-bifurcated-fiber-insplorion-software\/","title":{"rendered":"Insplorion Acoulyte (designed for Q-Sense Window Chamber, fits Q-Sense, Explorer E1 + Analyzer E4 Optics unit, Optical fiber probe, 90-degree bifurcated fiber, Insplorion software)"},"content":{"rendered":"<h3>Insplorion\u00a0Acoulyte A1<\/h3>\n<p>Po\u0142\u0105cz spektroskopi\u0119 optyczn\u0105 z QCM-D. Jednoczesne pomiary w czasie rzeczywistym za pomoc\u0105 spektroskopii nanoplazmonicznej (NPS) i mikrowagi kwarcowej z monitorowaniem rozpraszania (QCM-D).<\/p>\n<p>Kluczowe cechy<br \/>\nInsplorion Acoulyte umo\u017cliwia po\u0142\u0105czenie label-free technik optycznych i akustycznych w czasie rzeczywistym. Ta pot\u0119\u017cna kombinacja zapewnia dost\u0119p do uzupe\u0142niaj\u0105cych si\u0119 informacji, kt\u00f3re pomog\u0105 w zrozumieniu z\u0142o\u017conych proces\u00f3w powierzchniowych i cienkowarstwowych.<\/p>\n<p>InsplorionTM Aculyte umo\u017cliwia jednoczesne pomiary w czasie rzeczywistym za pomoc\u0105 NanoPlasmonic Sensing (NPS) firmy Insplorion i mikrowagi z kryszta\u0142u kwarcu Q-Sense z monitorowaniem rozpraszania (QCM-D)<\/p>\n<p>Dane w czasie rzeczywistym dotycz\u0105ce zmian masy suchej (optycznej), masy mokrej (akustycznej) i lepkospr\u0119\u017cysto\u015bci jednocze\u015bnie, dla tej samej pr\u00f3bki i na tej samej powierzchni.<\/p>\n<p>Informacje uzupe\u0142niaj\u0105ce, kt\u00f3re pomog\u0105 w zrozumieniu z\u0142o\u017conych proces\u00f3w powierzchniowych i cienkowarstwowych.<\/p>\n<p>Zmierz procesy dyfuzji i uzyskaj profilowanie g\u0142\u0119boko\u015bci grubych warstw (&gt;100 nm).<\/p>\n<p>Po\u0142\u0105czenie NPS i QCM-D<\/p>\n<p>Insplorion Acoulyte posiada wszystkie niezb\u0119dne komponenty sprz\u0119towe i programowe do dodawania pomiar\u00f3w NPS do przyrz\u0105du Q-Sense Explorer (E1) lub analizatora (E4), gdy jest wyposa\u017cony w modu\u0142 okienkowy Q-Sense (QWM 401).<\/p>\n<p><a href=\"https:\/\/nlab.pl\/wp-content\/uploads\/2026\/04\/Insplorion-Acoulyte_PI-1.pdf\" target=\"_blank\" rel=\"noopener\">SPECYFIKACJA<\/a><\/p>\n<h3 data-section-id=\"1kvghtu\" data-start=\"69\" data-end=\"93\"><span role=\"text\"><strong data-start=\"73\" data-end=\"93\">Komora pomiarowa<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"95\" data-end=\"224\">\n<thead data-start=\"95\" data-end=\"122\">\n<tr data-start=\"95\" data-end=\"122\">\n<th class=\"\" data-start=\"95\" data-end=\"106\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"106\" data-end=\"122\" data-col-size=\"md\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"152\" data-end=\"224\">\n<tr data-start=\"152\" data-end=\"224\">\n<td data-start=\"152\" data-end=\"171\" data-col-size=\"sm\">Komora pomiarowa<\/td>\n<td data-col-size=\"md\" data-start=\"171\" data-end=\"224\">Okre\u015blana przez modu\u0142 okienkowy Q-Sense (QWM 401)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"226\" data-end=\"229\" \/>\n<h3 data-section-id=\"z826yx\" data-start=\"231\" data-end=\"246\"><span role=\"text\"><strong data-start=\"235\" data-end=\"246\">Sensory<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"248\" data-end=\"465\">\n<thead data-start=\"248\" data-end=\"275\">\n<tr data-start=\"248\" data-end=\"275\">\n<th class=\"\" data-start=\"248\" data-end=\"259\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"259\" data-end=\"275\" data-col-size=\"sm\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"305\" data-end=\"465\">\n<tr data-start=\"305\" data-end=\"333\">\n<td data-start=\"305\" data-end=\"315\" data-col-size=\"sm\">Wymiary<\/td>\n<td data-start=\"315\" data-end=\"333\" data-col-size=\"sm\">\u015arednica 14 mm<\/td>\n<\/tr>\n<tr data-start=\"334\" data-end=\"376\">\n<td data-start=\"334\" data-end=\"344\" data-col-size=\"sm\">Pod\u0142o\u017ce<\/td>\n<td data-start=\"344\" data-end=\"376\" data-col-size=\"sm\">Sensory QCM-D z pow\u0142ok\u0105 SiO\u2082<\/td>\n<\/tr>\n<tr data-start=\"377\" data-end=\"421\">\n<td data-start=\"377\" data-end=\"392\" data-col-size=\"sm\">Powierzchnia<\/td>\n<td data-col-size=\"sm\" data-start=\"392\" data-end=\"421\">Nanostrukturyzowane z\u0142oto<\/td>\n<\/tr>\n<tr data-start=\"422\" data-end=\"465\">\n<td data-start=\"422\" data-end=\"444\" data-col-size=\"sm\">Standardowe pow\u0142oki<\/td>\n<td data-col-size=\"sm\" data-start=\"444\" data-end=\"465\">SiO\u2082, Al\u2082O\u2083, TiO\u2082<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"467\" data-end=\"470\" \/>\n<h3 data-section-id=\"hgo4iz\" data-start=\"472\" data-end=\"505\"><span role=\"text\"><strong data-start=\"476\" data-end=\"505\">Charakterystyka pomiarowa<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"507\" data-end=\"930\">\n<thead data-start=\"507\" data-end=\"534\">\n<tr data-start=\"507\" data-end=\"534\">\n<th class=\"\" data-start=\"507\" data-end=\"518\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"518\" data-end=\"534\" data-col-size=\"md\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"564\" data-end=\"930\">\n<tr data-start=\"564\" data-end=\"612\">\n<td data-start=\"564\" data-end=\"581\" data-col-size=\"sm\">\u0179r\u00f3d\u0142o \u015bwiat\u0142a<\/td>\n<td data-col-size=\"md\" data-start=\"581\" data-end=\"612\">Lampa wolframowo-halogenowa<\/td>\n<\/tr>\n<tr data-start=\"613\" data-end=\"644\">\n<td data-start=\"613\" data-end=\"624\" data-col-size=\"sm\">Czu\u0142o\u015b\u0107*<\/td>\n<td data-col-size=\"md\" data-start=\"624\" data-end=\"644\">0,03 monowarstwy<\/td>\n<\/tr>\n<tr data-start=\"645\" data-end=\"682\">\n<td data-start=\"645\" data-end=\"674\" data-col-size=\"sm\">\u015arednica plamki pomiarowej<\/td>\n<td data-col-size=\"md\" data-start=\"674\" data-end=\"682\">3 mm<\/td>\n<\/tr>\n<tr data-start=\"683\" data-end=\"747\">\n<td data-start=\"683\" data-end=\"707\" data-col-size=\"sm\">Rozdzielczo\u015b\u0107 czasowa<\/td>\n<td data-col-size=\"md\" data-start=\"707\" data-end=\"747\">Do 10 punkt\u00f3w pomiarowych na sekund\u0119<\/td>\n<\/tr>\n<tr data-start=\"748\" data-end=\"810\">\n<td data-start=\"748\" data-end=\"770\" data-col-size=\"sm\">Typowy poziom szumu<\/td>\n<td data-col-size=\"md\" data-start=\"770\" data-end=\"810\">&lt; 0,01 nm (w zakresie d\u0142ugo\u015bci fali)<\/td>\n<\/tr>\n<tr data-start=\"811\" data-end=\"849\">\n<td data-start=\"811\" data-end=\"834\" data-col-size=\"sm\">Zakres d\u0142ugo\u015bci fali<\/td>\n<td data-col-size=\"md\" data-start=\"834\" data-end=\"849\">450\u20131000 nm<\/td>\n<\/tr>\n<tr data-start=\"850\" data-end=\"930\">\n<td data-start=\"850\" data-end=\"874\" data-col-size=\"sm\">Wp\u0142yw na pomiar QCM-D<\/td>\n<td data-col-size=\"md\" data-start=\"874\" data-end=\"930\">Pomiar QCM-D nie jest zak\u0142\u00f3cany przez modu\u0142 Acoulyte<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"932\" data-end=\"1014\">* Warto\u015b\u0107 oszacowana dla monowarstwy cz\u0105steczek albuminy surowicy bydl\u0119cej (BSA).<\/p>\n<hr data-start=\"1016\" data-end=\"1019\" \/>\n<h3 data-section-id=\"rukqsv\" data-start=\"1021\" data-end=\"1057\"><span role=\"text\"><strong data-start=\"1025\" data-end=\"1057\">Wymiary (szer. \u00d7 g\u0142. \u00d7 wys.)<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1059\" data-end=\"1200\">\n<thead data-start=\"1059\" data-end=\"1086\">\n<tr data-start=\"1059\" data-end=\"1086\">\n<th class=\"\" data-start=\"1059\" data-end=\"1070\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"1070\" data-end=\"1086\" data-col-size=\"sm\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1116\" data-end=\"1200\">\n<tr data-start=\"1116\" data-end=\"1149\">\n<td data-start=\"1116\" data-end=\"1133\" data-col-size=\"sm\">Modu\u0142 Acoulyte<\/td>\n<td data-col-size=\"sm\" data-start=\"1133\" data-end=\"1149\">8 \u00d7 5 \u00d7 3 cm<\/td>\n<\/tr>\n<tr data-start=\"1150\" data-end=\"1200\">\n<td data-start=\"1150\" data-end=\"1182\" data-col-size=\"sm\">Jednostka optyczna Insplorion<\/td>\n<td data-col-size=\"sm\" data-start=\"1182\" data-end=\"1200\">25 \u00d7 27 \u00d7 9 cm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1202\" data-end=\"1205\" \/>\n<h3 data-section-id=\"xvadt2\" data-start=\"1207\" data-end=\"1229\"><span role=\"text\"><strong data-start=\"1211\" data-end=\"1229\">Oprogramowanie<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1231\" data-end=\"1606\">\n<thead data-start=\"1231\" data-end=\"1258\">\n<tr data-start=\"1231\" data-end=\"1258\">\n<th class=\"\" data-start=\"1231\" data-end=\"1242\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"1242\" data-end=\"1258\" data-col-size=\"md\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1288\" data-end=\"1606\">\n<tr data-start=\"1288\" data-end=\"1331\">\n<td data-start=\"1288\" data-end=\"1318\" data-col-size=\"sm\">Kompatybilne oprogramowanie<\/td>\n<td data-col-size=\"md\" data-start=\"1318\" data-end=\"1331\">Insplorer<\/td>\n<\/tr>\n<tr data-start=\"1332\" data-end=\"1388\">\n<td data-start=\"1332\" data-end=\"1352\" data-col-size=\"sm\">System operacyjny<\/td>\n<td data-col-size=\"md\" data-start=\"1352\" data-end=\"1388\">Kompatybilny z Microsoft Windows<\/td>\n<\/tr>\n<tr data-start=\"1389\" data-end=\"1490\">\n<td data-start=\"1389\" data-end=\"1417\" data-col-size=\"sm\">Format danych wyj\u015bciowych<\/td>\n<td data-col-size=\"md\" data-start=\"1417\" data-end=\"1490\">ASCII (kompatybilny z dowolnym oprogramowaniem do tworzenia wykres\u00f3w)<\/td>\n<\/tr>\n<tr data-start=\"1491\" data-end=\"1606\">\n<td data-start=\"1491\" data-end=\"1515\" data-col-size=\"sm\">Analizowane parametry<\/td>\n<td data-col-size=\"md\" data-start=\"1515\" data-end=\"1606\">Odczyt wieloparametrowy (np. d\u0142ugo\u015b\u0107 fali rezonansowej oraz ekstynkcja w maksimum LSPR)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1608\" data-end=\"1611\" \/>\n<h2 data-section-id=\"xl69zq\" data-start=\"1613\" data-end=\"1634\">Pomiar jest prosty<\/h2>\n<p data-start=\"1636\" data-end=\"1718\">Rozpocz\u0119cie pomiaru Acoulyte jest \u0142atwe. Poszczeg\u00f3lne kroki przedstawiono poni\u017cej:<\/p>\n<ol data-start=\"1720\" data-end=\"1960\">\n<li data-section-id=\"4lr125\" data-start=\"1720\" data-end=\"1780\">Zamontowa\u0107 sensor Acoulyte w module okienkowym Q-Sense.<\/li>\n<li data-section-id=\"3er2rn\" data-start=\"1781\" data-end=\"1834\">Zamontowa\u0107 modu\u0142 okienkowy w urz\u0105dzeniu Q-Sense.<\/li>\n<li data-section-id=\"1gwqij2\" data-start=\"1835\" data-end=\"1894\">Pod\u0142\u0105czy\u0107 uk\u0142ad fluidyczny i pod\u0142\u0105czy\u0107 modu\u0142 Acoulyte.<\/li>\n<li data-section-id=\"x3n3sw\" data-start=\"1895\" data-end=\"1960\">Skonfigurowa\u0107 pomiar w oprogramowaniu Insplorer oraz Q-Soft.<\/li>\n<\/ol>","protected":false},"excerpt":{"rendered":"<h3>Insplorion\u00a0Acoulyte A1<\/h3>\n<p>Po\u0142\u0105cz spektroskopi\u0119 optyczn\u0105 z QCM-D. Jednoczesne pomiary w czasie rzeczywistym za pomoc\u0105 spektroskopii nanoplazmonicznej (NPS) i mikrowagi kwarcowej z monitorowaniem rozpraszania (QCM-D).<\/p>","protected":false},"featured_media":6634,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"obszar-zastosowan":[35,34,31,29],"product_brand":[],"product_cat":[235],"product_tag":[],"class_list":["post-4070","product","type-product","status-publish","has-post-thumbnail","obszar-zastosowan-energetyka-i-magazynowanie-energii","obszar-zastosowan-nanotechnologia-monowarstwy-powloki-funkcjonalne","obszar-zastosowan-chemia-i-biochemia-analityczna-sensory-analiza-sladowa","obszar-zastosowan-edukacja-i-laboratoria-badawcze","product_cat-l-spr","first","instock","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product\/4070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/media\/6634"}],"wp:attachment":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/media?parent=4070"}],"wp:term":[{"taxonomy":"obszar-zastosowan","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/obszar-zastosowan?post=4070"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_brand?post=4070"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_cat?post=4070"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_tag?post=4070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}