{"id":4116,"date":"2026-02-16T12:58:57","date_gmt":"2026-02-16T11:58:57","guid":{"rendered":"https:\/\/nlab.idve.pl\/produkt\/multi-autolab-cabinet\/"},"modified":"2026-06-29T22:39:45","modified_gmt":"2026-06-29T20:39:45","slug":"multi-autolab-cabinet","status":"publish","type":"product","link":"https:\/\/nlab.pl\/en\/product\/multi-autolab-cabinet\/","title":{"rendered":"Multi Autolab Cabinet"},"content":{"rendered":"<div class=\"n4sEPd\">\n<div class=\"QFw9Te BLojaf\">\n<p class=\"NQSJo\"><span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Multi Autolab\/M101 to wszechstronny i niedrogi wielokana\u0142owy potencjostat\/galwanostat.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Jako wielokana\u0142owa wersja kompaktowego potencjostatu Autolab PGSTAT101, M101 zosta\u0142 zaprojektowany do obs\u0142ugi r\u00f3\u017cnorodnych eksperyment\u00f3w elektrochemicznych.<\/span><\/span> <span class=\"jCAhz ChMk0b\"><span class=\"ryNqvb\">Ka\u017cdy modu\u0142 M101 dzia\u0142a jako niezale\u017cny potencjostat, umo\u017cliwiaj\u0105c jednoczesne prowadzenie do 12 r\u00f3\u017cnych eksperyment\u00f3w w oddzielnych ogniwach elektrochemicznych.<\/span><\/span><\/p>\n<p class=\"NQSJo\">System umo\u017cliwia prac\u0119 z wieloma komputerami. Wbudowany HUB USB powala podzieli\u0107 sterowanie cz\u0119\u015bci\u0105 modu\u0142\u00f3w na maksymalnie 3 komputery, daj\u0105c jeszcze wi\u0119ksz\u0105 niezale\u017cno\u015b\u0107 w pracy w laboratoriach z kilkoma u\u017cytkownikami.<\/p>\n<\/div>\n<p>Obudowa umo\u017cliwia instalacj\u0119 modu\u0142\u00f3w elektrochemicznych AUTM101 lub modu\u0142\u00f3w rozszerze\u0144 w dowolnym momencie po zakupie oferuj\u0105c w ten spos\u00f3b perspektywiczne urz\u0105dzenie do dynamicznie rozwijaj\u0105cego si\u0119 laboratorium. Multipotencjostat obs\u0142uguje modu\u0142y AUTM101, i do pojedynczego modu\u0142u elektrochemicznego mo\u017cna doda\u0107 jeden z modu\u0142\u00f3w rozszerzaj\u0105cych: FRA32M \u2013 do pomiar\u00f3w EIS; BA \u2013 modu\u0142 bipotencjostatu; EQCM \u2013 modu\u0142 mikrowagi kwarcowej; MUX \u2013 modu\u0142 multipleksera; pX1000 \u2013 modu\u0142 do monitorowania temperatury, pH (pX) i dodatkowego sygna\u0142u potencja\u0142owego.<\/p>\n<p><strong>Specyfikacja techniczna modu\u0142u AUTM101<br \/>\nDownloads:\u00a0<a href=\"https:\/\/nlab.pl\/wp-content\/uploads\/2026\/03\/Autolab-portfolio.pdf\" target=\"_blank\" rel=\"noopener\">broszura<\/a>,\u00a0<a href=\"https:\/\/nlab.pl\/wp-content\/uploads\/2026\/03\/Autolab-specs.pdf\" target=\"_blank\" rel=\"noopener\">parametry techniczne<\/a>. Instrukcja obs\u0142ugi\u00a0<a href=\"https:\/\/nlab.pl\/wp-content\/uploads\/2026\/02\/nova-user-manual.pdf\" target=\"_blank\" rel=\"noopener\">NOVA<\/a>.<\/strong><\/p>\n<table width=\"280\">\n<tbody>\n<tr>\n<td width=\"140\">Parametry potencja\u0142owe<\/td>\n<td width=\"140\"><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Potencja\u0142 maksymalny (WE \u2013 CE)<\/td>\n<td width=\"140\">\u00b1 10V<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Dok\u0142adno\u015b\u0107 przyk\u0142adanego potencja\u0142u<\/td>\n<td width=\"140\">\u00b10.2% ustawienia \u00b12 mV<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Rozdzielczo\u015b\u0107 przyk\u0142adanego potencja\u0142u<\/td>\n<td width=\"140\">150 \u00b5V<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Szybko\u015b\u0107 narastania potencja\u0142u<\/td>\n<td width=\"140\">&lt; 300 ns<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Pasmo przenoszenia<\/td>\n<td width=\"140\">10 kHz \/ 100 kHz \/ 1 MHz<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Zakres mierzonego potencja\u0142u<\/td>\n<td width=\"140\">\u00b110 V<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Dok\u0142adno\u015b\u0107 mierzonego potencja\u0142u<\/td>\n<td width=\"140\">0.2% \u00b12 mV<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Rozdzielczo\u015b\u0107 mierzonego potencja\u0142u (ADC):<\/td>\n<td width=\"140\">300 \u00b5V<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Sygna\u0142y DC<\/td>\n<td width=\"140\">3 \u00b5V, wzmocnienie 100<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Sygna\u0142y AC<\/td>\n<td width=\"140\">1.3 \u03bcV (opcja FRA32M)<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Impedancja wej\u015bciowa elektrometru<\/td>\n<td width=\"140\">&gt;100 GOhm<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Pasmo przenoszenia elektrometru<\/td>\n<td width=\"140\">&gt; 4 MHz<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Second Sense (S2)<\/td>\n<td width=\"140\">Opcja pX1000<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Maksymalny potencja\u0142 S2<\/td>\n<td width=\"140\">\u00b1 10V<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Parametry Pr\u0105dowe<\/td>\n<td width=\"140\"><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Pr\u0105d maksymalny<\/td>\n<td width=\"140\">\u00b1 100 mA<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Zakres pr\u0105dowy<\/td>\n<td width=\"140\">10 nA do 100 mA w 7 zakresach<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Dok\u0142adno\u015b\u0107 przyk\u0142adanego pr\u0105du<\/td>\n<td width=\"140\">\u00b1 0.2% pr\u0105du i \u00b1 0.2% zakresu pr\u0105dowego<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Rozdzielczo\u015b\u0107 przyk\u0142adanego pr\u0105du<\/td>\n<td width=\"140\">0.015% zakresu pr\u0105dowego<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">(10 nA zakresu pr\u0105dowego)<\/td>\n<td width=\"140\">(1.5 pA)<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Dok\u0142adno\u015b\u0107 mierzonego pr\u0105du<\/td>\n<td width=\"140\">\u00b1 0.2% pr\u0105du i \u00b1 0.2% zakresu pr\u0105dowego<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Rozdzielczo\u015b\u0107 mierzonego pr\u0105du (ADC):<\/td>\n<td width=\"140\">30 fA (przy zakresie 10 nA)<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Sygna\u0142y DC<\/td>\n<td width=\"140\">30 fA (przy zakresie 1 nA)<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Sygna\u0142y AC<\/td>\n<td width=\"140\">\u2013<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Inne parametry<\/td>\n<td width=\"140\"><\/td>\n<\/tr>\n<tr>\n<td width=\"140\">EIS<\/td>\n<td width=\"140\">Opcja FRA32M 10 \u00b5Hz \u2013 1 MHz<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Skan analogowy<\/td>\n<td width=\"140\">\u2013<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Tryb Floating<\/td>\n<td width=\"140\">\u2013<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Tryb bipotencjostatu<\/td>\n<td width=\"140\">Opcja BA<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Kompensacja iR<\/td>\n<td width=\"140\">Tak, i-interrupt, positive feedback<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Wyj\u015bcia analogowe<\/td>\n<td width=\"140\">potencja\u0142 i pr\u0105d (opcjonalny Monitor cable)<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Szybko\u015b\u0107 skanowania \u2013 liniowego (analogowo)<\/td>\n<td width=\"140\">\u2013<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Szybko\u015b\u0107 skanowania \u2013 schodkowego<\/td>\n<td width=\"140\">0.1 \u00b5V\/s \u2013 145 V\/s<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Tryb pracy (liczba elektrod)<\/td>\n<td width=\"140\">2, 3, 4 lub 5<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Pomiar temperatury<\/td>\n<td width=\"140\">Opcja pX1000<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Gniazda na modu\u0142y rozszerzaj\u0105ce<\/td>\n<td width=\"140\">tak<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Wy\u015bwietlacz na panelu frontowym<\/td>\n<td width=\"140\">\u2013<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Interfejs<\/td>\n<td width=\"140\">USB<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Oprogramowanie steruj\u0105ce<\/td>\n<td width=\"140\">NOVA<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Wymiary (sz x g\u0142 x wys)<\/td>\n<td width=\"140\">9 x 15 x 21 cm3<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Waga<\/td>\n<td width=\"140\">2.1 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"140\">Zasilanie<\/td>\n<td width=\"140\">40 W, 100-240 V, 50\/60 Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><strong>Obudowa multipotencjostatu Autolab M101<\/strong><br \/>\nPodstawowy element multipotencjostatu M101 &#8211; obudowa z 12 portami na modu\u0142y elektrochemiczne lub modu\u0142y rozszerze\u0144.<\/p>","protected":false},"featured_media":7740,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"obszar-zastosowan":[36,35,34,31,29],"product_brand":[],"product_cat":[205],"product_tag":[],"class_list":["post-4116","product","type-product","status-publish","has-post-thumbnail","obszar-zastosowan-badania-nad-korozja-i-ochrona-powierzchni","obszar-zastosowan-energetyka-i-magazynowanie-energii","obszar-zastosowan-nanotechnologia-monowarstwy-powloki-funkcjonalne","obszar-zastosowan-chemia-i-biochemia-analityczna-sensory-analiza-sladowa","obszar-zastosowan-edukacja-i-laboratoria-badawcze","product_cat-autolab-moduly-dodatkowe","first","instock","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product\/4116","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/media\/7740"}],"wp:attachment":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/media?parent=4116"}],"wp:term":[{"taxonomy":"obszar-zastosowan","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/obszar-zastosowan?post=4116"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_brand?post=4116"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_cat?post=4116"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_tag?post=4116"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}