{"id":5265,"date":"2026-02-16T13:07:27","date_gmt":"2026-02-16T12:07:27","guid":{"rendered":"https:\/\/nlab.idve.pl\/produkt\/insplorion-x1-optics-unit-single-channel-x1-temperature-control-unit-high-temperature-measurement-chamber-insplorer-software\/"},"modified":"2026-06-29T22:44:29","modified_gmt":"2026-06-29T20:44:29","slug":"insplorion-x1-optics-unit-single-channel-x1-temperature-control-unit-high-temperature-measurement-chamber-insplorer-software","status":"publish","type":"product","link":"https:\/\/nlab.pl\/en\/product\/insplorion-x1-optics-unit-single-channel-x1-temperature-control-unit-high-temperature-measurement-chamber-insplorer-software\/","title":{"rendered":"Insplorion X1 (Optics unit single channel, X1 Temperature control unit,  High Temperature Measurement chamber, Insplorer software)"},"content":{"rendered":"<h3>Insplorion X1<\/h3>\n<p>Instrument Insplorion X1 zosta\u0142 opracowany do badania proces\u00f3w adsorpcji\/absorpcji gaz\u00f3w i innych interakcji materia\u0142owych, a tak\u017ce przemian fazowych (np. Tg) w cienkich warstwach polimerowych i materia\u0142ach istotnych dla katalizy in situ i w czasie rzeczywistym od temperatury otoczenia do 600\u00b0C.<\/p>\n<p>Kluczowe cechy<br \/>\nX1 mierzy zmiany strukturalne i\/lub dielektryczne praktycznie dowolnego nanomateria\u0142u lub cienkiej warstwy, zar\u00f3wno dielektrycznej, jak i metalicznej, indukowane m.in. sk\u0142adem gazu lub rampami temperatury. Insplorion X1 wykorzystuje zdalny odczyt optyczny, dzi\u0119ki czemu tylko chip czujnika musi by\u0107 umieszczony w komorze reakcyjnej.<\/p>\n<p>Ultraczu\u0142e pomiary w nanoskali<br \/>\nMonitoruj dynamiczne procesy w\/na nanocz\u0105stkach, nanostrukturach lub cienkich warstwach, w skali nanometrowej, dziesi\u0105tkach nanometr\u00f3w lub na ukrytym wewn\u0119trznym interfejsie grubych pow\u0142ok.<\/p>\n<p>Zintegrowana kontrola przep\u0142ywu gazu<br \/>\nSystem X1 mo\u017cna skonfigurowa\u0107 do wsp\u00f3\u0142pracy z maksymalnie 16 kontrolerami przep\u0142ywu masowego w celu precyzyjnej i terminowej kontroli mieszanki gaz\u00f3w i przep\u0142ywu.<\/p>\n<p>Analiza w czasie rzeczywistym<br \/>\nMierz z rozdzielczo\u015bci\u0105 czasow\u0105 poni\u017cej sekundy.<\/p>\n<p>\u0141atwy i solidny<br \/>\nSzybko rozpocznij prac\u0119 z oprogramowaniem Insplorer, kt\u00f3re oferuje pe\u0142n\u0105 kontrol\u0119 nad instrumentem.<\/p>\n<p>Pomiary in-situ<br \/>\nMierz w praktycznie odpowiednich warunkach w temperaturach do 600\u02daC.<\/p>\n<p>System podw\u00f3jnej pr\u00f3bki<br \/>\nMierz jednocze\u015bnie na maksymalnie dw\u00f3ch pr\u00f3bkach.<\/p>\n<p><a href=\"https:\/\/nlab.pl\/wp-content\/uploads\/2026\/02\/Insplorion-X1_PI.pdf\" target=\"_blank\" rel=\"noopener\">SPECYFIKACJA<\/a><\/p>\n<h3 data-section-id=\"1kvghtu\" data-start=\"80\" data-end=\"104\"><span role=\"text\"><strong data-start=\"84\" data-end=\"104\">Komora pomiarowa<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"106\" data-end=\"465\">\n<thead data-start=\"106\" data-end=\"133\">\n<tr data-start=\"106\" data-end=\"133\">\n<th class=\"\" data-start=\"106\" data-end=\"117\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"117\" data-end=\"133\" data-col-size=\"md\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"163\" data-end=\"465\">\n<tr data-start=\"163\" data-end=\"220\">\n<td data-start=\"163\" data-end=\"187\" data-col-size=\"sm\">Pozycja chipa sensora<\/td>\n<td data-col-size=\"md\" data-start=\"187\" data-end=\"220\">Pojedynczy lub podw\u00f3jny kana\u0142<\/td>\n<\/tr>\n<tr data-start=\"221\" data-end=\"266\">\n<td data-start=\"221\" data-end=\"233\" data-col-size=\"sm\">Przy\u0142\u0105cza<\/td>\n<td data-col-size=\"md\" data-start=\"233\" data-end=\"266\">Wlot 1\/8 cala, wylot 1\/4 cala<\/td>\n<\/tr>\n<tr data-start=\"267\" data-end=\"367\">\n<td data-start=\"267\" data-end=\"299\" data-col-size=\"sm\">Regulacja przep\u0142ywu masowego*<\/td>\n<td data-col-size=\"md\" data-start=\"299\" data-end=\"367\">Mo\u017cliwo\u015b\u0107 pod\u0142\u0105czenia do 16 regulator\u00f3w przep\u0142ywu masowego (MFC)<\/td>\n<\/tr>\n<tr data-start=\"368\" data-end=\"406\">\n<td data-start=\"368\" data-end=\"380\" data-col-size=\"sm\">Materia\u0142y<\/td>\n<td data-col-size=\"md\" data-start=\"380\" data-end=\"406\">Kwarc, stal nierdzewna<\/td>\n<\/tr>\n<tr data-start=\"407\" data-end=\"465\">\n<td data-start=\"407\" data-end=\"428\" data-col-size=\"sm\">Zakres temperatury<\/td>\n<td data-col-size=\"md\" data-start=\"428\" data-end=\"465\">Od temperatury pokojowej do 600\u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"467\" data-end=\"583\">* Nie zawiera w zestawie. Oprogramowanie Insplorer kompatybilne z regulatorami przep\u0142ywu masowego firmy Bronkhorst.<\/p>\n<hr data-start=\"585\" data-end=\"588\" \/>\n<h3 data-section-id=\"z826yx\" data-start=\"590\" data-end=\"605\"><span role=\"text\"><strong data-start=\"594\" data-end=\"605\">Sensory<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"607\" data-end=\"842\">\n<thead data-start=\"607\" data-end=\"634\">\n<tr data-start=\"607\" data-end=\"634\">\n<th class=\"\" data-start=\"607\" data-end=\"618\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"618\" data-end=\"634\" data-col-size=\"sm\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"664\" data-end=\"842\">\n<tr data-start=\"664\" data-end=\"704\">\n<td data-start=\"664\" data-end=\"674\" data-col-size=\"sm\">Wymiary<\/td>\n<td data-col-size=\"sm\" data-start=\"674\" data-end=\"704\">9,5 \u00d7 9,5 mm, grubo\u015b\u0107 1 mm<\/td>\n<\/tr>\n<tr data-start=\"705\" data-end=\"748\">\n<td data-start=\"705\" data-end=\"715\" data-col-size=\"sm\">Pod\u0142o\u017ce<\/td>\n<td data-col-size=\"sm\" data-start=\"715\" data-end=\"748\">Szk\u0142o kwarcowe (fused silica)<\/td>\n<\/tr>\n<tr data-start=\"749\" data-end=\"793\">\n<td data-start=\"749\" data-end=\"764\" data-col-size=\"sm\">Powierzchnia<\/td>\n<td data-col-size=\"sm\" data-start=\"764\" data-end=\"793\">Nanostrukturyzowane z\u0142oto<\/td>\n<\/tr>\n<tr data-start=\"794\" data-end=\"842\">\n<td data-start=\"794\" data-end=\"817\" data-col-size=\"sm\">Standardowe pow\u0142oki*<\/td>\n<td data-col-size=\"sm\" data-start=\"817\" data-end=\"842\">Au, SiO\u2082, Al\u2082O\u2083, TiO\u2082<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"844\" data-end=\"915\">* Mo\u017cliwo\u015b\u0107 zam\u00f3wienia sensor\u00f3w z niestandardowymi cienkimi pow\u0142okami.<\/p>\n<hr data-start=\"917\" data-end=\"920\" \/>\n<h3 data-section-id=\"hgo4iz\" data-start=\"922\" data-end=\"955\"><span role=\"text\"><strong data-start=\"926\" data-end=\"955\">Charakterystyka pomiarowa<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"957\" data-end=\"1275\">\n<thead data-start=\"957\" data-end=\"984\">\n<tr data-start=\"957\" data-end=\"984\">\n<th class=\"\" data-start=\"957\" data-end=\"968\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"968\" data-end=\"984\" data-col-size=\"md\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1014\" data-end=\"1275\">\n<tr data-start=\"1014\" data-end=\"1086\">\n<td data-start=\"1014\" data-end=\"1032\" data-col-size=\"sm\">\u0179r\u00f3d\u0142o \u015bwiat\u0142a*<\/td>\n<td data-col-size=\"md\" data-start=\"1032\" data-end=\"1086\">Lampa wolframowo-halogenowa, min. \u017cywotno\u015b\u0107 2000 h<\/td>\n<\/tr>\n<tr data-start=\"1087\" data-end=\"1124\">\n<td data-start=\"1087\" data-end=\"1116\" data-col-size=\"sm\">\u015arednica plamki pomiarowej<\/td>\n<td data-col-size=\"md\" data-start=\"1116\" data-end=\"1124\">2 mm<\/td>\n<\/tr>\n<tr data-start=\"1125\" data-end=\"1182\">\n<td data-start=\"1125\" data-end=\"1151\" data-col-size=\"sm\">Rozdzielczo\u015b\u0107 czasowa**<\/td>\n<td data-col-size=\"md\" data-start=\"1151\" data-end=\"1182\">Do 10 punkt\u00f3w pomiarowych\/s<\/td>\n<\/tr>\n<tr data-start=\"1183\" data-end=\"1233\">\n<td data-start=\"1183\" data-end=\"1205\" data-col-size=\"sm\">Typowy poziom szumu<\/td>\n<td data-col-size=\"md\" data-start=\"1205\" data-end=\"1233\">&lt; 0,01 nm (d\u0142ugo\u015b\u0107 fali)<\/td>\n<\/tr>\n<tr data-start=\"1234\" data-end=\"1275\">\n<td data-start=\"1234\" data-end=\"1260\" data-col-size=\"sm\">Zakres d\u0142ugo\u015bci fali***<\/td>\n<td data-col-size=\"md\" data-start=\"1260\" data-end=\"1275\">450\u20131000 nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"1277\" data-end=\"1426\">* Dost\u0119pne opcje niestandardowe i cz\u0119\u015bci zamienne.<br data-start=\"1328\" data-end=\"1331\" \/>** Przy cz\u0119stotliwo\u015bci pr\u00f3bkowania 1 Hz.<br data-start=\"1372\" data-end=\"1375\" \/>*** Dost\u0119pne niestandardowe zakresy d\u0142ugo\u015bci fali.<\/p>\n<hr data-start=\"1428\" data-end=\"1431\" \/>\n<h3 data-section-id=\"rukqsv\" data-start=\"1433\" data-end=\"1469\"><span role=\"text\"><strong data-start=\"1437\" data-end=\"1469\">Wymiary (szer. \u00d7 g\u0142. \u00d7 wys.)<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1471\" data-end=\"1738\">\n<thead data-start=\"1471\" data-end=\"1498\">\n<tr data-start=\"1471\" data-end=\"1498\">\n<th class=\"\" data-start=\"1471\" data-end=\"1482\" data-col-size=\"md\">Parametr<\/th>\n<th class=\"\" data-start=\"1482\" data-end=\"1498\" data-col-size=\"sm\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1528\" data-end=\"1738\">\n<tr data-start=\"1528\" data-end=\"1602\">\n<td data-start=\"1528\" data-end=\"1582\" data-col-size=\"md\">Reaktor wysokotemperaturowy z os\u0142on\u0105 bezpiecze\u0144stwa<\/td>\n<td data-col-size=\"sm\" data-start=\"1582\" data-end=\"1602\">28 \u00d7 28 \u00d7 100 cm<\/td>\n<\/tr>\n<tr data-start=\"1603\" data-end=\"1653\">\n<td data-start=\"1603\" data-end=\"1635\" data-col-size=\"md\">Jednostka optyczna Insplorion<\/td>\n<td data-col-size=\"sm\" data-start=\"1635\" data-end=\"1653\">25 \u00d7 27 \u00d7 9 cm<\/td>\n<\/tr>\n<tr data-start=\"1654\" data-end=\"1738\">\n<td data-start=\"1654\" data-end=\"1700\" data-col-size=\"md\">Jednostka kontroli temperatury (2 elementy)<\/td>\n<td data-col-size=\"sm\" data-start=\"1700\" data-end=\"1738\">25 \u00d7 27 \u00d7 9 cm oraz 22 \u00d7 40 \u00d7 9 cm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1740\" data-end=\"1743\" \/>\n<h3 data-section-id=\"xvadt2\" data-start=\"1745\" data-end=\"1767\"><span role=\"text\"><strong data-start=\"1749\" data-end=\"1767\">Oprogramowanie<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1769\" data-end=\"2141\">\n<thead data-start=\"1769\" data-end=\"1796\">\n<tr data-start=\"1769\" data-end=\"1796\">\n<th class=\"\" data-start=\"1769\" data-end=\"1780\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"1780\" data-end=\"1796\" data-col-size=\"md\">Specyfikacja<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1826\" data-end=\"2141\">\n<tr data-start=\"1826\" data-end=\"1869\">\n<td data-start=\"1826\" data-end=\"1856\" data-col-size=\"sm\">Kompatybilne oprogramowanie<\/td>\n<td data-col-size=\"md\" data-start=\"1856\" data-end=\"1869\">Insplorer<\/td>\n<\/tr>\n<tr data-start=\"1870\" data-end=\"1926\">\n<td data-start=\"1870\" data-end=\"1890\" data-col-size=\"sm\">System operacyjny<\/td>\n<td data-col-size=\"md\" data-start=\"1890\" data-end=\"1926\">Kompatybilny z Microsoft Windows<\/td>\n<\/tr>\n<tr data-start=\"1927\" data-end=\"2028\">\n<td data-start=\"1927\" data-end=\"1955\" data-col-size=\"sm\">Format danych wyj\u015bciowych<\/td>\n<td data-col-size=\"md\" data-start=\"1955\" data-end=\"2028\">ASCII (kompatybilny z dowolnym oprogramowaniem do tworzenia wykres\u00f3w)<\/td>\n<\/tr>\n<tr data-start=\"2029\" data-end=\"2141\">\n<td data-start=\"2029\" data-end=\"2053\" data-col-size=\"sm\">Analizowane parametry<\/td>\n<td data-col-size=\"md\" data-start=\"2053\" data-end=\"2141\">Odczyt wieloparametrowy (np. d\u0142ugo\u015b\u0107 fali rezonansowej i ekstynkcja w maksimum LSPR)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Insplorion X1 Instrument Insplorion X1 zosta\u0142 opracowany do badania proces\u00f3w adsorpcji\/absorpcji gaz\u00f3w i innych interakcji materia\u0142owych, a tak\u017ce przemian fazowych (np. Tg) w cienkich warstwach polimerowych i materia\u0142ach istotnych dla katalizy in situ i w czasie rzeczywistym od temperatury otoczenia do 600\u00b0C. Kluczowe cechy X1 mierzy zmiany strukturalne i\/lub dielektryczne praktycznie dowolnego nanomateria\u0142u lub cienkiej [&hellip;]<\/p>\n","protected":false},"featured_media":6617,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"obszar-zastosowan":[35,34,29],"product_brand":[],"product_cat":[235],"product_tag":[],"class_list":["post-5265","product","type-product","status-publish","has-post-thumbnail","obszar-zastosowan-energetyka-i-magazynowanie-energii","obszar-zastosowan-nanotechnologia-monowarstwy-powloki-funkcjonalne","obszar-zastosowan-edukacja-i-laboratoria-badawcze","product_cat-l-spr","first","instock","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product\/5265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/media\/6617"}],"wp:attachment":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/media?parent=5265"}],"wp:term":[{"taxonomy":"obszar-zastosowan","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/obszar-zastosowan?post=5265"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_brand?post=5265"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_cat?post=5265"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_tag?post=5265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}