{"id":6882,"date":"2026-04-02T16:25:39","date_gmt":"2026-04-02T14:25:39","guid":{"rendered":"https:\/\/nlab.idve.pl\/produkt\/insplorion-s2-flow-2\/"},"modified":"2026-06-29T22:43:21","modified_gmt":"2026-06-29T20:43:21","slug":"insplorion-s2-flow-2","status":"publish","type":"product","link":"https:\/\/nlab.pl\/en\/product\/insplorion-s2-flow-2\/","title":{"rendered":"Insplorion S2 &#8211; Flow"},"content":{"rendered":"<p>Insplorion S2 Flow<\/p>\n<p>Wszechstronno\u015b\u0107 jest na wyci\u0105gni\u0119cie r\u0119ki. Prosty, elegancki i wytrzyma\u0142y. Idealny instrument do bada\u0144 biomolekularnych.<\/p>\n<p><a href=\"https:\/\/nlab.pl\/wp-content\/uploads\/2026\/04\/Insplorion-S2_PI.pdf\" target=\"_blank\" rel=\"noopener\">SPECYFIKACJA<\/a><\/p>\n<h2 data-section-id=\"ukottg\" data-start=\"59\" data-end=\"78\"><span role=\"text\"><strong data-start=\"62\" data-end=\"78\">Specyfikacja<\/strong><\/span><\/h2>\n<h3 data-section-id=\"1xdutb2\" data-start=\"80\" data-end=\"117\"><span role=\"text\"><strong data-start=\"84\" data-end=\"117\">Komora przep\u0142ywowa (Flowcell)<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"119\" data-end=\"599\">\n<thead data-start=\"119\" data-end=\"138\">\n<tr data-start=\"119\" data-end=\"138\">\n<th class=\"\" data-start=\"119\" data-end=\"130\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"130\" data-end=\"138\" data-col-size=\"sm\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"160\" data-end=\"599\">\n<tr data-start=\"160\" data-end=\"207\">\n<td data-start=\"160\" data-end=\"188\" data-col-size=\"sm\">Pozycja chipa sensorowego<\/td>\n<td data-col-size=\"sm\" data-start=\"188\" data-end=\"207\">Podw\u00f3jny kana\u0142*<\/td>\n<\/tr>\n<tr data-start=\"208\" data-end=\"263\">\n<td data-start=\"208\" data-end=\"224\" data-col-size=\"sm\">Typ dozowania<\/td>\n<td data-col-size=\"sm\" data-start=\"224\" data-end=\"263\">Pompa strzykawkowa z p\u0119tl\u0105 pr\u00f3bkow\u0105<\/td>\n<\/tr>\n<tr data-start=\"264\" data-end=\"298\">\n<td data-start=\"264\" data-end=\"289\" data-col-size=\"sm\">Martwa obj\u0119to\u015b\u0107 pr\u00f3bki<\/td>\n<td data-col-size=\"sm\" data-start=\"289\" data-end=\"298\">20 \u00b5L<\/td>\n<\/tr>\n<tr data-start=\"299\" data-end=\"346\">\n<td data-start=\"299\" data-end=\"333\" data-col-size=\"sm\">Standardowa obj\u0119to\u015b\u0107 strzykawki<\/td>\n<td data-col-size=\"sm\" data-start=\"333\" data-end=\"346\">250 \u00b5L **<\/td>\n<\/tr>\n<tr data-start=\"347\" data-end=\"398\">\n<td data-start=\"347\" data-end=\"373\" data-col-size=\"sm\">Typowy zakres przep\u0142ywu<\/td>\n<td data-col-size=\"sm\" data-start=\"373\" data-end=\"398\">12,5 \u2013 250 \u00b5L\/min ***<\/td>\n<\/tr>\n<tr data-start=\"399\" data-end=\"438\">\n<td data-start=\"399\" data-end=\"428\" data-col-size=\"sm\">Standardowa p\u0119tla pr\u00f3bkowa<\/td>\n<td data-col-size=\"sm\" data-start=\"428\" data-end=\"438\">200 \u00b5L<\/td>\n<\/tr>\n<tr data-start=\"439\" data-end=\"477\">\n<td data-start=\"439\" data-end=\"451\" data-col-size=\"sm\">Materia\u0142y<\/td>\n<td data-col-size=\"sm\" data-start=\"451\" data-end=\"477\">Szk\u0142o szafirowe, tytan<\/td>\n<\/tr>\n<tr data-start=\"478\" data-end=\"540\">\n<td data-start=\"478\" data-end=\"501\" data-col-size=\"sm\">Uszczelki i przewody<\/td>\n<td data-col-size=\"sm\" data-start=\"501\" data-end=\"540\">PTFE, FPM oraz elastomer silikonowy<\/td>\n<\/tr>\n<tr data-start=\"541\" data-end=\"599\">\n<td data-start=\"541\" data-end=\"562\" data-col-size=\"sm\">Zakres temperatury<\/td>\n<td data-col-size=\"sm\" data-start=\"562\" data-end=\"599\">15 \u2013 45 \u00b0C ze stabilno\u015bci\u0105 0,1 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"601\" data-end=\"689\">* Kana\u0142y ustawione szeregowo<br data-start=\"630\" data-end=\"633\" \/>** Mo\u017cliwo\u015b\u0107 konfiguracji<br data-start=\"659\" data-end=\"662\" \/>*** Sterowane programowo<\/p>\n<hr data-start=\"691\" data-end=\"694\" \/>\n<h3 data-section-id=\"z826yx\" data-start=\"696\" data-end=\"711\"><span role=\"text\"><strong data-start=\"700\" data-end=\"711\">Sensory<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"713\" data-end=\"948\">\n<thead data-start=\"713\" data-end=\"732\">\n<tr data-start=\"713\" data-end=\"732\">\n<th class=\"\" data-start=\"713\" data-end=\"724\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"724\" data-end=\"732\" data-col-size=\"sm\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"754\" data-end=\"948\">\n<tr data-start=\"754\" data-end=\"794\">\n<td data-start=\"754\" data-end=\"764\" data-col-size=\"sm\">Wymiary<\/td>\n<td data-col-size=\"sm\" data-start=\"764\" data-end=\"794\">9,5 \u00d7 9,5 mm, grubo\u015b\u0107 1 mm<\/td>\n<\/tr>\n<tr data-start=\"795\" data-end=\"842\">\n<td data-start=\"795\" data-end=\"805\" data-col-size=\"sm\">Pod\u0142o\u017ce<\/td>\n<td data-col-size=\"sm\" data-start=\"805\" data-end=\"842\">Krzemionka topiona (fused silica)<\/td>\n<\/tr>\n<tr data-start=\"843\" data-end=\"888\">\n<td data-start=\"843\" data-end=\"859\" data-col-size=\"sm\">Powierzchnia*<\/td>\n<td data-col-size=\"sm\" data-start=\"859\" data-end=\"888\">Nanostrukturyzowane z\u0142oto<\/td>\n<\/tr>\n<tr data-start=\"889\" data-end=\"948\">\n<td data-start=\"889\" data-end=\"913\" data-col-size=\"sm\">Standardowe pow\u0142oki**<\/td>\n<td data-col-size=\"sm\" data-start=\"913\" data-end=\"948\">Niepowlekane, SiO\u2082, Al\u2082O\u2083, TiO\u2082<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"950\" data-end=\"1080\">* Dost\u0119pne r\u00f3wnie\u017c nanostruktury srebra na zam\u00f3wienie<br data-start=\"1004\" data-end=\"1007\" \/>** Mo\u017cliwo\u015b\u0107 zam\u00f3wienia sensor\u00f3w z niestandardowymi cienkimi warstwami<\/p>\n<hr data-start=\"1082\" data-end=\"1085\" \/>\n<h3 data-section-id=\"8arz7r\" data-start=\"1087\" data-end=\"1118\"><span role=\"text\"><strong data-start=\"1091\" data-end=\"1118\">Charakterystyka pomiaru<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1120\" data-end=\"1521\">\n<thead data-start=\"1120\" data-end=\"1139\">\n<tr data-start=\"1120\" data-end=\"1139\">\n<th class=\"\" data-start=\"1120\" data-end=\"1131\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"1131\" data-end=\"1139\" data-col-size=\"md\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1161\" data-end=\"1521\">\n<tr data-start=\"1161\" data-end=\"1233\">\n<td data-start=\"1161\" data-end=\"1175\" data-col-size=\"sm\">Typ pomiaru<\/td>\n<td data-col-size=\"md\" data-start=\"1175\" data-end=\"1233\">Bez znacznik\u00f3w (Label-free) \u2013 nanosensing plazmoniczny<\/td>\n<\/tr>\n<tr data-start=\"1234\" data-end=\"1316\">\n<td data-start=\"1234\" data-end=\"1252\" data-col-size=\"sm\">\u0179r\u00f3d\u0142o \u015bwiat\u0142a*<\/td>\n<td data-col-size=\"md\" data-start=\"1252\" data-end=\"1316\">Lampa wolframowo-halogenowa, minimalna \u017cywotno\u015b\u0107 2000 godzin<\/td>\n<\/tr>\n<tr data-start=\"1317\" data-end=\"1356\">\n<td data-start=\"1317\" data-end=\"1346\" data-col-size=\"sm\">\u015arednica plamki pomiarowej<\/td>\n<td data-col-size=\"md\" data-start=\"1346\" data-end=\"1356\">1,5 mm<\/td>\n<\/tr>\n<tr data-start=\"1357\" data-end=\"1421\">\n<td data-start=\"1357\" data-end=\"1381\" data-col-size=\"sm\">Rozdzielczo\u015b\u0107 czasowa<\/td>\n<td data-col-size=\"md\" data-start=\"1381\" data-end=\"1421\">Do 10 punkt\u00f3w pomiarowych na sekund\u0119<\/td>\n<\/tr>\n<tr data-start=\"1422\" data-end=\"1485\">\n<td data-start=\"1422\" data-end=\"1446\" data-col-size=\"sm\">Typowy poziom szumu**<\/td>\n<td data-start=\"1446\" data-end=\"1485\" data-col-size=\"md\">&lt; 0,01 nm (w domenie d\u0142ugo\u015bci fali)<\/td>\n<\/tr>\n<tr data-start=\"1486\" data-end=\"1521\">\n<td data-start=\"1486\" data-end=\"1509\" data-col-size=\"sm\">G\u0142\u0119boko\u015b\u0107 sondowania<\/td>\n<td data-col-size=\"md\" data-start=\"1509\" data-end=\"1521\">Do 30 nm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"1523\" data-end=\"1629\">* Dost\u0119pne opcje niestandardowe oraz wymienne \u017ar\u00f3d\u0142a \u015bwiat\u0142a<br data-start=\"1584\" data-end=\"1587\" \/>** Przy cz\u0119stotliwo\u015bci pr\u00f3bkowania 1 Hz<\/p>\n<hr data-start=\"1631\" data-end=\"1634\" \/>\n<h3 data-section-id=\"26lqdf\" data-start=\"1636\" data-end=\"1650\"><span role=\"text\"><strong data-start=\"1640\" data-end=\"1650\">System<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1652\" data-end=\"1754\">\n<thead data-start=\"1652\" data-end=\"1671\">\n<tr data-start=\"1652\" data-end=\"1671\">\n<th class=\"\" data-start=\"1652\" data-end=\"1663\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"1663\" data-end=\"1671\" data-col-size=\"sm\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1693\" data-end=\"1754\">\n<tr data-start=\"1693\" data-end=\"1737\">\n<td data-start=\"1693\" data-end=\"1703\" data-col-size=\"sm\">Wymiary<\/td>\n<td data-start=\"1703\" data-end=\"1737\" data-col-size=\"sm\">Szer. 65 \u00d7 G\u0142. 42 \u00d7 Wys. 36 cm<\/td>\n<\/tr>\n<tr data-start=\"1738\" data-end=\"1754\">\n<td data-start=\"1738\" data-end=\"1745\" data-col-size=\"sm\">Masa<\/td>\n<td data-col-size=\"sm\" data-start=\"1745\" data-end=\"1754\">30 kg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<hr data-start=\"1756\" data-end=\"1759\" \/>\n<h3 data-section-id=\"xvadt2\" data-start=\"1761\" data-end=\"1783\"><span role=\"text\"><strong data-start=\"1765\" data-end=\"1783\">Oprogramowanie<\/strong><\/span><\/h3>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1785\" data-end=\"2155\">\n<thead data-start=\"1785\" data-end=\"1804\">\n<tr data-start=\"1785\" data-end=\"1804\">\n<th class=\"\" data-start=\"1785\" data-end=\"1796\" data-col-size=\"sm\">Parametr<\/th>\n<th class=\"\" data-start=\"1796\" data-end=\"1804\" data-col-size=\"md\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"1826\" data-end=\"2155\">\n<tr data-start=\"1826\" data-end=\"1870\">\n<td data-start=\"1826\" data-end=\"1853\" data-col-size=\"sm\">Oprogramowanie steruj\u0105ce<\/td>\n<td data-start=\"1853\" data-end=\"1870\" data-col-size=\"md\">InControl 1.0<\/td>\n<\/tr>\n<tr data-start=\"1871\" data-end=\"1930\">\n<td data-start=\"1871\" data-end=\"1891\" data-col-size=\"sm\">System operacyjny<\/td>\n<td data-col-size=\"md\" data-start=\"1891\" data-end=\"1930\">Kompatybilne z Microsoft Windows 10<\/td>\n<\/tr>\n<tr data-start=\"1931\" data-end=\"2058\">\n<td data-start=\"1931\" data-end=\"1959\" data-col-size=\"sm\">Format danych wyj\u015bciowych<\/td>\n<td data-col-size=\"md\" data-start=\"1959\" data-end=\"2058\">Format w\u0142asny (proprietary) z eksportem do CSV\/TSV dla \u0142atwej analizy w zewn\u0119trznych programach<\/td>\n<\/tr>\n<tr data-start=\"2059\" data-end=\"2155\">\n<td data-start=\"2059\" data-end=\"2083\" data-col-size=\"sm\">Analizowane parametry<\/td>\n<td data-col-size=\"md\" data-start=\"2083\" data-end=\"2155\">Odczyt wieloparametrowy (efektywna zmiana st\u0119\u017cenia powierzchniowego)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p><strong>Insplorion S2 Flow<\/strong>\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 <a href=\"https:\/\/nlab.pl\/wp-content\/uploads\/2026\/04\/Insplorion-S2_PI.pdf\" target=\"_blank\" rel=\"noopener\">SPECYFIKACJA<\/a><\/p>\n<p>Wszechstronno\u015b\u0107 jest na wyci\u0105gni\u0119cie r\u0119ki. Prosty, elegancki i wytrzyma\u0142y. Idealny instrument do bada\u0144 biomolekularnych.<\/p>\n<p><strong>Insplorion S2<\/strong> jest wyposa\u017cony w dwukana\u0142ow\u0105 komor\u0119 przep\u0142ywow\u0105 do label-free\u00a0 bada\u0144 w czasie rzeczywistym interakcji molekularnych i proces\u00f3w adsorpcji powierzchniowej. System umo\u017cliwia prawdziwe pomiary w nanoskali w promieniu kilkudziesi\u0119ciu nm powierzchni\/pr\u00f3bki, z doskona\u0142\u0105 kontrol\u0105 przep\u0142ywu pr\u00f3bek i bufor\u00f3w.<\/p>\n<p><strong>Zintegrowana i zautomatyzowana obs\u0142uga p\u0142yn\u00f3w<\/strong> &#8211;\u00a0Zautomatyzowana obs\u0142uga przep\u0142ywu z kolejk\u0105 polece\u0144 oprogramowania, 6-drogowym zaworem wtryskowym i pomp\u0105 strzykawkow\u0105 z nieprzerwanym przep\u0142ywem. Zintegrowana wymiana bufora i operacja p\u0142ukania.<\/p>\n<p><strong>Dok\u0142adna kontrola temperatury<\/strong> &#8211;\u00a0Szybka i stabilna regulacja temperatury w zakresie od 15 do 45\u00b0C i wahaniach poni\u017cej 0,05\u00b0C.<\/p>\n<p><strong>\u0141atwa obs\u0142uga<\/strong> &#8211;\u00a0Pr\u00f3bki s\u0105 dostarczane za pomoc\u0105 zintegrowanego systemu obs\u0142ugi p\u0142yn\u00f3w, z pe\u0142n\u0105 dost\u0119pno\u015bci\u0105 dla u\u017cytkownika, co zapewnia \u0142atwo\u015b\u0107 obs\u0142ugi i dok\u0142adn\u0105 kontrol\u0119. Dzia\u0142anie jest zautomatyzowane dzi\u0119ki oprogramowaniu Insplorion InControl. Zdejmowana za pomoc\u0105 jednego uchwytu komora przep\u0142ywowa z oddzieln\u0105 tac\u0105 no\u015bn\u0105 czujnika u\u0142atwia codzienn\u0105 obs\u0142ug\u0119 i konserwacj\u0119.<\/p>\n<p><strong>System podw\u00f3jnej pr\u00f3bki &#8211;\u00a0<\/strong>Mierz jednocze\u015bnie na maksymalnie dw\u00f3ch kana\u0142ach.\u00a0 Uwzgl\u0119dnij kontrole w swoich eksperymentach lub przetestuj dwa warunki na raz.<\/p>\n<p>Insplorion S2 nadaje si\u0119 do ka\u017cdego biomateria\u0142u i mo\u017ce z \u0142atwo\u015bci\u0105 obs\u0142ugiwa\u0107 r\u00f3\u017cne rodzaje biopr\u00f3bek: \u2013 Lipidy \u2013 Bia\u0142ka \u2013 Kwasy nukleinowe \u2013 Wirusy \u2013 Biofilmy \u2013 Biominera\u0142y \u2013 Hydro\u017cele<\/p>\n<p><strong>Wszechstronno\u015b\u0107 &#8211;\u00a0<\/strong>Insplorion S2 umo\u017cliwia wiele analiz procesu: \u2013 Adsorpcja molekularna na r\u00f3\u017cnych powierzchniach \u2013 Tworzenie dwuwarstwy lipidowej \u2013 Interakcje zale\u017cne od temperatury \u2013 Zmiany konformacyjne \u2013 Rozpoznawanie biomolekularne \u2013 Zaszczepianie biomineralizacji \u2013 Tworzenie biofilmu \u2013 Dynamika \u0142adowania i roz\u0142adowywania<\/p>\n<p>&nbsp;<\/p>","protected":false},"featured_media":390,"template":"","meta":{"_acf_changed":false,"inline_featured_image":false},"obszar-zastosowan":[],"product_brand":[],"product_cat":[235],"product_tag":[],"class_list":["post-6882","product","type-product","status-publish","has-post-thumbnail","product_cat-l-spr","first","instock","purchasable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product\/6882","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/media\/390"}],"wp:attachment":[{"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/media?parent=6882"}],"wp:term":[{"taxonomy":"obszar-zastosowan","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/obszar-zastosowan?post=6882"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_brand?post=6882"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_cat?post=6882"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/nlab.pl\/en\/wp-json\/wp\/v2\/product_tag?post=6882"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}