DRP-110
DRP-11L
DRP-C110
DRP-C11L
|
Screen printed carbon electrodes
Working (4 mm diameter) and counter electrodes made of carbon. Ideal for working with 50 μL volume (ref. DRP-110) or by Introducing them in solution (ref. DRP-C110). Also available with Ag/AgCl reference electrode (refs. DRP-11L and DRP-C11L).
|
DRP-150
|
Screen-printed Carbon Electrodes (Aux.: Pt ; Ref.: Ag)
Working (4 mm diameter) electrode is made of carbon, counter electrode is made of platinum, reference electrode is made of silver and electric contacts are made of silver. Ideal for working with 50 µL volume.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
|
DRP-220AT
DRP-220BT
DRP-C220AT
DRP-C220BT
DRP-C223AT
DRP-C223BT
|
Screen-printed Gold Electrodes
Electrodes screen-printed with high (AT) and low (BT) temperature curing inks which may have different properties depending on the application. Working electrode is available in two sizes: 4 mm or 1.6 mm diameter. Plus a specific design for work in solution.
Working (4 or 1.6 mm diameter) and counter electrodes are made of gold, whereas reference electrode and electric contacts are made of silver. Ideal for working with 50 µL volume (refs. 220AT, 220BT, C223AT, C223BT) or by introducing them in solution (refs. C220AT, C220BT).
AT models: Electrodes screen-printed with high temperature curing ink. BT models: Electrodes screen-printed with low temperature curing ink.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
|
DRP-250AT
DRP-250BT
|
Screen-printed Gold Electrodes (Aux.: Pt ; Ref.: Ag)
Working (4 mm diameter) electrode is made of gold, counter electrode is made of platinum, reference electrode is made of Ag and electric contacts are made of silver. Ideal for working with 50 µL volume.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
|
DRP-C013
DRP-010
|
Screen-printed Silver Electrodes (Aux.: C ; Ref.: Ag)
Working (1.6 mm or 4 mm diameter) electrode is made of Silver and counter electrode is made of Carbon; reference electrode and electric contacts are made of Silver. For electrochemical measurements or in-situ EC-SERS. Ideal for working with 50 µL volume.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
|
DRP-550
DRP-C550
DRP-550BT
|
Screen-printed Platinum Electrodes
Working (4 mm diameter) and counter electrodes made of platinum. Ideal for working with 50 µL volume (ref. DRP-550) or by Introducing them in solution (ref. DRP-C550). Also available in low temperature curing ink (ref. 550BT).
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
|
DRP-810
|
Screen-Printed Ruthenium Oxide Electrodes (Aux.: C; Ref.: Ag)
Working (4 mm diameter) electrode is made of Ruthenium Oxide, counter electrode is made of Carbon, reference electrode is made of Silver and electric contacts are made of Silver. It is ideal for working with 50 µL volume.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height)
|
DRP-910
|
Screen-printed Palladium Electrodes (Aux.: C ; Ref.: Ag)
Working (4 mm diameter) electrode is made of Palladium, counter electrode is made of Carbon, reference electrode is made of silver and electric contacts are made of silver. Ideal for working with 50 µL volume.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
|
DRP-ITO10
|
Optically Transparent ITO Screen-printed Electrode
These disposable ITO Electrodes (ref.ITO10) made in a plastic substrate are based of a ITO Working Electrode with a Carbon Counter Electrode and a Silver reference electrode. Specially designed for Spectroelectrochemical applications.
Dimensions: 33 x 10 x 0.175 mm
|
DRP-P10
|
Optically Transparent PEDOT Screen-printed Electrode
These disposable PEDOT Electrodes (ref.P10) made in a plastic substrate are based of a PEDOT Working Electrode with a Carbon Counter Electrode and a Silver reference electrode. Specially designed for ElectroChemiLuminiscence or Spectroelectrochemical applications.
Dimensions: 33 x 10 x 0.175 mm (Length x Width x Height).
|
DRP-AUTR10
|
Screen-printed Gold Optically Transparent Electrode
Screen-printed electrodes on a transparent plastic substrate with a thin layer gold working electrode deposited by sputtering process. The thin layer provide enough transparency and a very flat surface is achieved. Gold working electrode (4 mm diameter), carbon counter electrode and silver reference electrode system ideal for working with low volume of sample.
Dimensions: 33 x 10 x 0.5 mm
|
DRP-COTE10
|
Carbon Optically Transparent Screen-printed Electrode
Disposable Carbon Optically Transparent electrodes (ref. COTE10) made in a plastic transparent substrate with a working electrode of Single Walled Carbon Nanotubes (SWCNTs). This thin layer working electrode is combined with screen-printed carbon auxiliary and silver reference electrodes, ideal for performing spectroelectrochemical experiments.
Dimensions: 33 x 10 x 0.175 mm.
|
DRP-BIOFV1
|
Screen-Printed Electrodes for Biofuel Cells
DropSens launches Screen-Printed Electrodes with an appropriate configuration to develop self-powered electrochromic biosensors with a potential of being "instrumentless" sensoric devices for analyte detection.
Dimensions: 3.3 x 1.0 x 0.0175 cm (Length x Width x Height).
|
DRP-PW-AU10
|
Gold Electrode over flexible plastic substrate
Gold electrodes made on flexible plastic substrate with a working electrode of 4 mm. They allow working with low volumes of sample, being suitable for decentralized assays, to develop specific (bio)sensors and other electrochemical studies
|
DRP-BI10
DRP-SB10
DRP-CR10
DRP- NI10
DRP-SN10
DRP-AL10
DRP-MO10
DRP-PB10
DRP-TA10
DRP-W10
DRP-ST10
DRP-CST10
DRP-CO10
|
Thick-Film Electrodes - Bismuth, Antimony, Chromium, Nickel, Tin, Aluminium, Molybdenum, Lead, Tantalum, Tungsten, Carbon Steel and Cobalt
Disposable Thick-Film Electrodes. Suitable for working with microvolumes and ideal for decentralized assays or to develop specific (bio)sensors. Useful for undergraduate lab to avoid tedious polishing of solid electrodes.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
BI10 - Bismuth
SB10 - Antimony
CR10 - Chrome
I10 - Nickel
SN10 - Tin
MO10 - Molybdenum
PB10 - Lead
TA10 - Tantalum
W10 - Vanadium
ST10 - Steel
CST10 - Carbon steel
AL10 - Aluminum
CO10 - Cobalt
|
DRP-BDD10
DRP-CBDD10
|
Thick-film Boron Doped Diamond Electrodes (Aux.: C, Ref.: Ag)
Miniaturised Boron Doped Diamond working electrode (3.6 mm diameter) over ceramic substrates. Auxiliary electrode is made of Carbon and reference electrodes is made of Silver. Innovative electrode material, BDD has an enhanced electrochemical window. Ideal for working with 50 µL volume.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
|
DRP-SPESMIX
|
Screen-printed Electrodes (MIX)
Mix of screen-printed electrodes with different working electrodes materials: carbon (ref. 110), gold AT or BT (refs. 220AT and 220BT) and platinum (550). The possibility to check the different electrochemical behavior of these references previous developing your own application.
|
DRP-OTEMIX
|
Optically Transparent Electrodes Mix
Mix of transparent working electrodes with different electrode materials: PEDOT (ref. P10), ITO (ref. ITO10), Gold (ref. AUTR10) and Single-Walled Carbon Nanotubes (ref. COTE10). Check the different performances of these references previously developing your spectroelectrochemical experiments.
|
DRP-AUMIX
|
Screen-printed Gold Electrodes (MIX)
Mix of Gold screen-printed electrodes combining references of high (AT) and low (BT) temperature curing inks which may have different properties depending on the application. Working electrode is available in two sizes: 4 mm or 1.6 mm diameter.
· AT models: Electrodes screen-printed with high temperature curing ink. · BT models: Electrodes screen-printed with low temperature curing ink.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
|
DRP-8X110
|
8X Screen-printed Carbon Electrodes
Screen-printed electrochemical array formed by eight 3-electrode electrochemical cells with carbon-based working electrodes. Specially designed for the development of multiple simultaneous analysis. The system can be customised with other working electrode materials such as gold, platinum or silver.
Dimensions: 3.4 x 7.9 x 0.1 cm (Length x Width x Height)
|
DRP-8X220AT
|
8X Screen-printed Gold Electrodes
Screen-printed electrochemical array formed by eight 3-electrode electrochemical cells with high temperature gold-based working electrodes. Specially designed for the development of multiple simultaneous analysis. The system can be customised with other working electrode materials such as carbon modified with nanomaterials, platinum or silver.
Dimensions: 3.4 x 7.9 x 0.1 cm (Length x Width x Height).
|
DRP-8X550
|
8X Screen-printed Platinum Electrodes
Screen-printed electrochemical array formed by eight 3-electrode electrochemical cells with Platinum-based working electrodes. Specially designed for the development of multiple simultaneous analysis. The system is available also in carbon and gold and can be customised with other working electrode materials such as silver or carbon modified with nanomaterials.
Dimensions: 3.4 x 7.9 x 0.1 cm (Length x Width x Height).
|
DRP-4W110
|
4W Screen-printed Carbon Electrodes
Screen-printed electrode formed by four carbon working electrodes sharing auxiliary and reference electrode. These electrodes are aimed at detecting four signals simultaneously, allowing (differential) measurement of up to four analytes in the solution. The system can be customised with other working electrode materials such as gold, platinum or silver.
Dimensions: 3.8 x 2 x 0.1 cm (Length x Width x Height).
|
DRP-8W110
|
8W Screen-printed Carbon Electrodes
Screen-printed electrode formed by eight carbon working electrodes sharing auxiliary and reference electrode. These electrodes are aimed at detecting eight signals simultaneously, allowing (differential) measurement of up to eight analytes in the solution. The system can be customised with other working electrode materials such as gold, platinum or silver.
Dimensions: 3.8 x 2 x 0.1 cm (Length x Width x Height).
|
DRP-96X110
|
96X Screen-printed Carbon Electrodes
DropSens launches Electrochemical ELISA plates. This is a new screen-printed electrochemical array formed by 96 three-electrode electrochemical cells with carbon-based working electrodes. This electrochemical array is fixed in the bottom of a standard microtiter ELISA plate with 96 wells.
The system can be customised with other working electrode materials such as silver or carbon modified with nanomaterials.
Dimensions: 7.4 x 11 x 0.5 cm (Lenght x Width x Height) .
|
DRP-96X220
|
96X Screen-printed Gold Electrodes
DropSens launches Electrochemical ELISA plates. This is a new screen-printed electrochemical array formed by 96 three-electrode electrochemical cells with Gold -based working electrodes. This electrochemical array is fixed in the bottom of a standard microtiter ELISA plate with 96 wells.
The system can be customised with other working electrode materials such as silver or carbon modified with nanomaterials.
Dimensions: 7.4 x 11 x 0.5 cm (Lenght x Width x Height).
|
DRP-96X550
|
96X Screen-printed Platinum Electrodes
DropSens launches Electrochemical ELISA plates. This is a new screen-printed electrochemical array formed by 96 three-electrode electrochemical cells with Platinum -based working electrodes. This electrochemical array is fixed in the bottom of a standard microtiter ELISA plate with 96 wells.
The system can be customised with other working electrode materials such as silver or carbon modified with nanomaterials.
Dimensions: 7.4 x 11 x 0.5 cm (Lenght x Width x Height).
|
DRP-TLFCL110
DRP-TLFCL110S
DRP-TLFCL1110
DRP-TLFCL2222AT
|
Thin layer flow-cell screen-printed electrodes
Screen-printed electrodes integrated in one channel flow-cell. They are suitable for working with Flow Injection Analysis systems and also in batch mode. The transparent cover allows you an easy control of the sample volume.
|
DRP-TLFCL110-CIR
DRP-TLFCL210AT-CIR
DRP-TLFCL210BT-CIR
DRP-TLFCL510-CIR
DRP-TLFCL010-CIR
|
Thin layer flow-cell screen-printed electrodes, circular working electrode
Screen-printed electrodes integrated in one channel flow-cell, where working electrode is circular shaped with a diameter of 4 mm. They are suitable for working with Flow Injection Analysis systems and also in batch mode. The transparent cover allows you an easy control of the sample volume.
|
DRP-110STR
DRP-X1110STR
|
Screen-Printed Carbon Electrodes (SPCEs) modified with Streptavidin
DropSens launches Screen-Printed Carbon Electrodes (SPCEs) modified with Streptavidin. Streptavidin modified SPCEs provide a stable high affinity surface for a large amount of biotinylated molecules. These SPCEs are designed for the development of (bio) sensors with an enhanced electrochemical active area.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height)
|
DRP-8X110STR
|
8X Streptavidin modified Screen-printed Carbon Electrodes
Screen-printed electrochemical array formed by eight 3-electrode electrochemical cells with high streptavidin modified carbon-based working electrodes. Specially designed for the development of multiple simultaneous analysis. The system can be customised with other working electrode materials such as carbon modified with other nanomaterials.
Dimensions: 3.4 x 7.9 x 0.1 cm (Length x Width x Height)
|
DRP-96X110STR
|
Streptavidin modified 96X Screen-printed Carbon Electrodes
DropSens launches Electrochemical ELISA plates modified with Streptavidin. This is a new screen-printed electrochemical array formed by 96 three-electrode electrochemical cells with carbon-based working electrodes modified with Streptavidin that provides a stable high affinity surface for a large amount of biotinylated molecules. This electrochemical array is fixed in the bottom of a standard microtiter ELISA plate with 96 wells.
Dimensions: 7.4 x 11 x 0.5 cm (Lenght x Width x Height).
|
DRP-110XTR
DRP-X1110XTR
|
Screen-Printed Carbon Electrodes (SPCEs) modified with ExtrAvidin
DroSens launches Screen-Printed Carbon Electrodes (SPCEs) modified with ExtrAvidin. ExtrAvidin combines Avidin high specificity with low non-specific adsorption of Streptavidin. These SPCEs are designed for the development of (bio) sensors with an enhanced electrochemical active area.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height).
|
DRP-96X110XTR
|
ExtrAvidin modified 96X Screen-printed Carbon Electrodes
DropSens launches Electrochemical ELISA plates modified with ExtrAvidin. ExtrAvidin combines Avidin high specificity with low non-specific adsorption of Streptavidin. This electrochemical array is fixed in the bottom of a standard microtiter ELISA plate with 96 wells.
Dimensions: 7.4 x 11 x 0.5 cm (Lenght x Width x Height).
|
DRP-110PANI
DRP-X1110PANI
|
Screen-Printed Carbon Electrodes (SPCEs) modified with Polyaniline
DroSens launches Screen-Printed Carbon Electrodes (SPCEs) modified with Polyaniline. These SPCEs are designed for the development of (bio) sensors with an enhanced electrochemical active area.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height)
|
DRP-110PDP
|
Palladium particles modified SPEs
Palladium particles modified SPEs are ideal for the determination of hydrogen peroxide at a low detection potentials. These electrodes are recommended for the development of enzymatic biosensors based on oxidases.
|
DRP-110BI
DRP-X1110BI
|
Bismuth Oxide Modified Screen-printed Carbon Electrodes
These disposable carbon electrodes modified with bismuth (III) oxide are ideal for the environmental friendly determination of heavy metals at ppb levels.
Useful for research labs to avoid mercury based electrodes.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height)
|
DRP-110NI
DRP-X1110NI
|
Nickel Oxide Modified Screen-printed Carbon Electrodes
These disposable carbon electrodes modified with Nickel (II) Oxide (NiO) are designed for the electrocatalytic oxidation of small organic molecules such as carbohydrates and alcohols.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height)
|
DRP-110GPH
DRP-X1110GPH
|
Graphene Modified Screen-Printed Electrodes
DropSens launches Screen-Printed Carbon Electrodes (SPCEs) modified with Graphene as a carbon based nanomaterial.
Graphene SPCEs are designed for the development of (bio) sensors with an enhanced electrochemical active area.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height)
|
DRP-110GPHOX
DRP-X1110GPHOX
|
Graphene Oxide Modified Screen-Printed Electrodes
Screen-Printed Carbon Electrodes (SPCEs) modified with Graphene Oxide as a carbon based nanomaterial. Graphene Oxide SPCEs are designed for the development of (bio) sensors with an enhanced electrochemical active area.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height)
|
DRP-110RGPHOX
DRP-X1110RGPHOX
|
Reduced Graphene Oxide Modified Screen-Printed Electrodes
Screen-Printed Carbon Electrodes (SPCEs) modified with Reduced Graphene Oxide as a carbon based nanomaterial. Reduced Graphene Oxide SPCEs are designed for the development of (bio) sensors with an enhanced electrochemical active area.
Dimensions: 3.4 x 1.0 x 0.05 cm (Length x Width x Height)
|
DRP-110CNT
DRP-X1110CNT
DRP-110SWCNT
DRP-X1110SWCNT
|
Elektrody sitodrukowane węglowe modyfikowane nanorurkami węglowymi jedno- i wielościennymi
Elektrody węglowe modyfikowane nanorurkami węglowymi z grupami karboksylowymi pojedynczo- i wielościankowymi. Zaprojektowane do badań biosensorów o zwiększonej powierzchni aktywnej. Takie elektrody wykazują zwiększony transfer elektronów od klasycznych, a także zachowują właściwości elektrokatalityczne zwykłych nanorurek. Są stabilne, więc mogą być wykorzystywane w systemach FIA. Idealne do pracy w 50uL.
110CNT - Elektroda pracująca węglowa, modyfikowana nanorurkami węglowymi z grupami karboksylowymi wielościankowe, o średnicy 4mm, pomocnicza węglowa, referencyjna srebrowa.
110SWCNT - Elektroda pracująca węglowa, modyfikowana nanorurkami węglowymi z grupami karboksylowymi jednościankowe, pomocnicza węglowa, referencyjna srebrowa.
Rozmiar: 3,4 x 1,0 x 0,05 cm (długość, szerokość, grubość.)
Sugerowane akcesoria:
110CNT/110SWCNT - DSC, DSC4MMH, FLWCL, FLWCL-PEEK
|
DRP-96X110CNT
|
Elektrody sitodrukowane węglowe modyfikowane nanorurkami węglowymi z grupami karboksylowymi, płytka 96 celkowa
Elektrody sitodrukowane typu ELISA na 96 układów pomiarowych. Układ elektrod ustawionych na sztywno wg standardu ELISA.
96X110CNT – Każdy z układów ma WE- węglową modyfikowaną nanorurkami węglowymi z grupami karboksylowymi, CE – węglową, REF – srebraną.
Rozmiar: 7.4 x 11 x 0.5 cm (długość, szerokość, grubość.)
Sugerowane akcesoria:
96X110CNT – CONNECTOR96X, MAGNET96X
|
DRP- 96X110SWCNT
|
Elektrody sitodrukowane węglowe modyfikowane nanorurkami węglowymi z grupami karboksylowymi jednościennymi, płytka 96 celkowa
Elektrody sitodrukowane typu ELISA na 96 układów pomiarowych. Układ elektrod ustawionych na sztywno wg standardu ELISA.
96X110SWCNT – Każdy z układów ma WE- węglową modyfikowane nanorurkami węglowymi z grupami karboksylowymi jednościankowe, CE – węglową, REF – srebraną.
Rozmiar: 7.4 x 11 x 0.5 cm (długość, szerokość, grubość.)
Sugerowane akcesoria:
96X110SWCNT – CONNECTOR96X, MAGNET96X
|
DRP-110CNF
DRP-X1110CNF
|
Elektrody sitodrukowane węglowe modyfikowane nanorurkami węglowymi
110CNF - Elektroda pracująca węglowa, modyfikowana nanorurkami węglowymi o średnicy 4mm, pomocnicza węglowa, referencyjna srebrowa. Idealna do pracy w 50uL, zaprojektowana do badań (bio)sensorów.
X1110CNF - Elektroda pracująca węglowa, modyfikowana nanorurkami węglowymi, podwójna (do bipotencjostatu), pomocnicza węglowa, referencyjna srebrowa. Idealna do pracy w 50uL
Rozmiar: 3,4 x 1,0 x 0,05 cm (długość, szerokość, grubość.)
Sugerowane akcesoria:
110CNF - DSC, DSC4MMH, FLWCL, FLWCL-PEEK X1110CNF – BIDSC, BIDSC4MM, FLWCL-BI
|
DRP-110MC
DRP-X1110MC
|
Elektrody sitodrukowane węglowe modyfikowane mezoporowatym węglem
110MC - Elektroda pracująca węglowa średnicy 4mm, modyfikowana mezoporowatym węglem, pomocnicza węglowa, referencyjna srebrowa. Idealna do pracy w 50uL, zaprojektowana do badań sensorów ze zwiększoną powierzchnią aktywną.
X1110MC - Elektroda pracująca węglowa, modyfikowana modyfikowana mezoporowatym węglem, podwójna (do bipotencjostatu), pomocnicza węglowa, referencyjna srebrowa. Idealna do pracy w 50uL.
Rozmiar: 3,4 x 1,0 x 0,05 cm (długość, szerokość, grubość.)
Sugerowane akcesoria:
110MC - DSC, DSC4MMH, FLWCL, FLWCL-PEEK
X1110MC – BIDSC, BIDSC4MM, FLWCL-BI
|
DRP-110MNPH
|
SPE z węglem modyfikowanym mangan (II) ftalocyjaniną
SPE modyfikowane mangan (II) ftalocyjaniną są idealne do oznaczania nadtlenku wodoru przy niskim potencjale wykrywania. Elektrody te są zalecane do opracowywania enzymatycznych bioczujników opartych na oksydazach.
|
DRP- 110OMC
DRP- X1110OMC
|
Elektrody sitodrukowane węglowe modyfikowane uporządkowanym mezoporowatym węglem
110MC - Elektroda pracująca węglowa średnicy 4mm, modyfikowana uporządkowanym mezoporowatym węglem, pomocnicza węglowa, referencyjna srebrowa. Idealna do pracy w 50uL, zaprojektowana do badań sensorów ze zwiększoną powierzchnią aktywną.
X1110MC - Elektroda pracująca węglowa, modyfikowana modyfikowana uporządkowanym mezoporowatym węglem, podwójna (do bipotencjostatu), pomocnicza węglowa, referencyjna srebrowa. Idealna do pracy w 50uL.
Rozmiar: 3,4 x 1,0 x 0,05 cm (długość, szerokość, grubość.)
Sugerowane akcesoria:
110OMC - DSC, DSC4MMH, FLWCL, FLWCL- PEEK
X1110OMC – BIDSC, BIDSC4MM, FLWCL-BI
|
DRP-110GNP
DRP-X1110GNP
|